The SM Electrical Excited component models a three-phase electrical-excited synchronous induction machine with damper cage. The resistance and stray inductance of the stator is modeled directly in stator phases, then using space phasor transformation and a rotor-fixed Air Gap model. The resistance and stray inductance of the rotor's squirrel cage is modeled in two axes of the rotor-fixed coordinate system. Electrical excitation is modeled by converting excitation current and voltage to d-axis space phasors.
The following losses are modeled:
•
|
heat losses in the temperature dependent stator winding resistances
|
•
|
heat losses in the temperature dependent excitation winding resistance
|
•
|
optional, when enabled: heat losses in the temperature dependent damper cage resistances
|
•
|
brush losses in the excitation circuit
|
•
|
core losses (only eddy current losses, no hysteresis losses)
|
Whether a damper cage is present or not can be selected with Boolean parameter useDamperCage (default = true).