This document shows the example of T-shaped wall design calculation according to Eurocode 7. The design situation is based on Eurocode 7: Geotechnical Design Worked examples ANNEX A.4 and involves T-shaped gravity wall with that is required to support granular fill. The ground and the fill are both dry.